I.Foreword: CD50belongs to independent photoelectric smoke fire alarm, CD50W support alarm wireless transmission host, please check the model when the user purchase,
that can detect the smoke and alarm by sound and flash before the fire happens. It is built-in loud whistle, using the light top design principle and get the alarm light can be 360°visual. The housing is designed to complete rotary detachable buckle for easy to install and easy for maintenance as the dust-proof designed in appearance and easy to replace the batteries. It is adopted by self-adaption technology that can make dynamic compensation for the environment variation and the aging components to keep the detect sensitivity and extend the using time; it also can self-test in real time for the inner circuit for lasting working fine. It can be used at residences, internet bar, dance hall, coffee house, etc…
two:Features:
support three big alarm, independent sound and light alarmSupport two kinds of alarm methods, sound and flash & wireless transmission
wireless transmission network alarm (optional model CD50W)
360° all-round detection of smoke alarm, no dead ends, reliable
built-in high-sensitivity induction technology, reliable, safe
built-in 85dB sound and light alarm, effective reminder evacuation site;
ultra-low power microcontrollers + optoelectronic principles of technology, long standby battery life of 1 year
Full snap-fit patent structure of easy to install and no need commissioning
Elegantly designed, aesthetically pleasing appearance, dust-proof
Light top designed principle with alarm light 360°visual
Adopting self-adoption technology that can make dynamic compensation for environment variation and aging components to extend using time
Owning self-test function can test inner circuit real time to keep detector lasting working fine;
Adopting ultra-low power micro technology and photoelectric principle making standby time for long;
adopting high-performance photo of a collection of two bidirectional scattering patent technology, stable, reliable, accuracy;
Low battery alarm function, when the battery voltage lower than 6.8v, It will make warning tone out;
The housing is designed to full rotary detachable buckle of easy maintenance.
three.Technology Parameter
Power voltage |
DC9V(6F22 battery) |
Alarm Method |
Standalone/ wireless transmission for options |
Wireless transmission frequency |
CD50 independent detection alarm, CD50W wireless transmission (support) |
Wireless transmission distance |
Open distance ≥150 |
Static current |
<=10uA |
Alarm Current |
<=40mA |
Sounder level |
≥85dB |
Low voltage Alarm |
6.8V |
Wireless code rule |
C50W (1527, can skip code) |
Environment temperature |
-10°C~+60°C |
Relative humidity |
≤95%RH |
Working area |
60 square meters |
Installation height |
≥6m |
Smoke sensitivity |
II grade |
Products dimension |
100x100 x 34mm |
Packing box |
Color neutral |
Packing box dimension |
105*105*35MM |
four.How to use
Jump code setting
A. How to choose oscillating electrical resistance: to set the electrical resistance as 1.5M/3.3M/4.7M by slip stitch J2, to use difference slip stitch for relative electrical resistance
B. How to choose code: to set the A0 to A7 between host and alarm as address code as same with alarm host; set D0-D3 as date code for alarm area
Smoke sensitivity adjustment
A: If the sensitivity is not very good, with a Phillips screwdriver clockwise adjustment;
Install the battery DC9V(6F22 battery)
A. The installation is complete, To press the alarm button by testing alarm(TEST), LED light flash fast, if there is wireless, it will transmit a signal to host, also can test it by smoke (for sure working fine, you can test it weekly)
B. After installation, the Alarm should flash one time per 45 seconds, it will keep warning till air back to fresh when meet smoke,
Mark: Standalone Alarm no needs any setting
Installation Guides
installation steps
1.to drill two holes at the position of screw buckle
2.to put the expansion pipe into the hole
3.to put the base on the wall then nail the base by screw through the expansion pipe
4.to put the battery in and press the test button to test the device work or not (Remark: the passive and
negative of battery must be sure in correct position)
5.After the device be sure working fine, then aim buckle position of base and housing, and then twirl the housing by clockwise to the correct position to finish
Installation attention
No close to door, window, and beside fans as air around these them is under fast circulation that can influent the detecting sensitivity. For sure of working fine of detecting, you’d better clean it per six months, just need to take out of the battery, and brush it slightly by soft brush, then put the battery back to finish. It may make a wrong alarm as the non-normal temperature, just need to the around air circulation to stop the alarm noise, and the dust may makes wrong alarm, so it is necessary to keep clean as above instruction.