Reliable Autonomous Soft Start Optical Smoke Detector Alarm 10 Years

1000.0 pieces
MOQ
Reliable Autonomous Soft Start Optical Smoke Detector Alarm 10 Years
Features Gallery Product Description Request A Quote
Features
Specifications
Place Of Origin: Zhejiang, China
Brand Name: EVERSAFE
Model Number: ZA209
Type: Photoelectric, Standalone
Standard: EN14604:2005/AC:2008
Power Supply:: 1 Pc 3V Lithium Battery
Battery Service Lifetime: 10 Years
Fault Indicator: Yes
Low Battery Voltage: Will Be Indicated
Hush Mode: 10-min Silence
Non-disturb Mode: 10-hour Silence
User-friendly Test Sound Pattern: Soft Start
Anti-tamper Function: Yes
Certification: CPR Cert, ROHS, REACH, PAHS
Basic Infomation
Place of Origin: Zhejiang, China
Brand Name: EVERSAFE
Certification: CPR Cert, ROHS, REACH, PAHS
Model Number: ZA209
Payment & Shipping Terms
Packaging Details: 1. Each product's package includes 1 product label, 1 manual in A3 paper and 1 pc color box with size 115*45*115 mm. 2. Each product's package has our brand logo. 3. There are 60pcs in each outer carton with size 500*265*415 mm. 4. 1 20GP container can ho
Supply Ability: 12800 Piece/Pieces per Month
Product Description
Specifications

Product Name

Smoke Alarm

Type

Standalone, Photoelectric

Intent Use

Residential Fire Safety

Complied Standard

EN14604:2005/AC:2008

Certificates

CPR Certificate

Size

φ100*33.6mm

Color

White RAL9010

Net weight

91g (with battery)

Power Supply

1 pc 3V lithium battery with 10-year lifetime

Hush Mode

10-min silence for false alarm cause by other smoke

Non-disturb Mode 10-hour silence for fault or low battery voltage alarm to ensure good night
Anti-tamper Function yes

Low Battery Voltage & fault indicator

yes

Alarm sensitivity

0.100-0.160dB/m

Alarm Volume

>85dB(A) at 3 meters.

Operation current

<6uA(standby), <100mA(alarm)

Operating temperature

0 °C - 40 °C

Operating humidity

< 93 %

Mounting

Ceiling or wall

Warranty

3 years

Product lifetime

10 years

Accessories

Screws, dowels and battery

5 Status of Smoke Alarm

Standby Status

Red LED flashes once every 40 seconds indicating the smoke alarm is operating properly.

Alarm & Test Status

When the test button is pressed or when the smoke alarm senses particles of combustion and goes into alarm (constant pulsed sound), the red LED will flash once per second

Low Battery Voltage Status

An intermittent chirp with red LED flashes once every 40 seconds.

Fault Status

16 seconds after the alarm chirps every 40 seconds, the red light flashes once

Silence Mode Status

The red LED will flash once every 8 seconds after pressing the test button in alarm status

Installation

FAQ

Problems

Solutions

Smoke alarm does not sound when testing

NOTE: Press test button for at least 5 seconds while testing.

Please replace it with a new smoke alarm.

The alarm chirps with red LED flashing once every 40 seconds.

Please replace it with a new smoke alarm.

16 seconds after the alarm chirps every 40 seconds, the red light flashes once

(The alarm goes into fault mode)

Clean smoke alarm referring to the Maintenance and Cleaning section.

Change a new smoke alarm if the problem still exists.

Smoke alarm sounds unwanted alarms intermittently or when residents are cooking, taking showers, etc.

Press test button to pause alarm.

Clean smoke alarm. Please refer to the Maintenance and Cleaning section.

Move smoke alarm to new location and press test button.

The alarm sounds different from it is used to. It starts and stops.

Clean smoke alarm. Please refer to the Maintenance and Cleaning section.

If there are still failures during warranty, you can return to your retailer.

If the unit is out of warranty, please replace a new alarm.